Pressure Vacuum Breaker Backflow Assembly

Pressure Vacuum Breaker Assembly Installed with Valves


Backflow assembly and irrigation valve replacement was necessary to bring this existing Orlando irrigation system upto local code. The maximum installation height of the Watts 800 M4 pressure vacuum breaker backflow assembly is 36 inches high. The assembly must be installed a minimum of 12 inches higher than the tallest irrigation head to ensure that it continues to protect the potable water system. The configuration of the existing irrigation sprinkler system meant that a more sophisticated Watts 900 QT reduced pressure zone backflow assembly was required. This type of assembly is installed at a height of between 12 to 18 inches. The irrigation heads can be set at any height & the assembly will still provide complete protection for the potable water supply at either your home or business location.

Hessenauer Sprinkler Repair & Irrigation are state certified to carryout mandatory annual backflow tests. This test ensures that your backflow is operating correctly and is not allowing any contaminants into the potable water system.

New Rain Bird DV100SS  irrigation system valves were installed so they are located below grade. The backflow assembly and irrigation valve replacement was necessary as the valve location, in relation to the backflow was not to local code.

If backflow assembly and irrigation valve replacement is required at either your home or business within the Orlando and Central Florida area you can call us now for a quick response on 407-302-2227 with any questions.